Model Name:
LXCD-40~300
Ultrasonic water meter
![]() |
Features: .Widely range,Range ratio up to 1:500 .This product is suitable for the accurate measurement of the total meter flow of industrial water and urban water supply sub house- holds.It solves the problem that the traditional water meter starting flowrate is large,,small flow measurement is not accurate,it also applies to non-powered site |
Technical Parameters | |||||||||
Maximum operating pressure |
1.6MPa | ||||||||
Water temperature range |
0.1-50℃ | ||||||||
Executive standard |
ISO 4064:2005, GB/T778-2007; Accuracy lev el:LV2 | ||||||||
Structure type |
One-piece | ||||||||
Battery level |
Built-in lithium battery,More than 15 years of working life | ||||||||
Protection level |
IP 68 ,Working environment temperature:-25℃-+55℃ | ||||||||
Screen display |
Can display 12 digits Cumulative amount (the decimal point can be adjusted);Four instantaneous flow | ||||||||
Water volume display mode |
1. The net cumulative amount (NET)2. Forward water volume (FWD) 3.Forward water volume and back flow water volume Alternate display (FWD/BCK) | ||||||||
Signal output |
Pulse output (open drain) 4-20mA output Modbus RTU / RS485, M-Bus | ||||||||
Connection method |
Threaded connection:DN40mm,Flange connection:DN50mm-DN300mm IOS standard | ||||||||
Environmental rating |
Climate and mechanical environment rating Class C,Electromagnetic environment level E1 | ||||||||
Head loss level |
△ P16 | ||||||||
Actual performance parameter | |||||||||
Flowrate m³ |
Nominal diameter | ||||||||
DN 40-1 1/2 |
DN 50-2 |
DN 65-2.5 |
DN 80-3 |
DN 100-4 |
DN 150-6 |
DN 200-8 |
DN 250-10 |
DN 300-12 | |
Q5 |
65 |
65 |
70 |
100 |
150 |
350 |
550 |
1300 |
1300 |
Q3 |
40 |
40 |
50 |
63 |
100 |
250 |
400 |
1000 |
1000 |
Q2 |
0.125 |
0.125 |
0.128 |
0.200 |
0.320 |
0.600 |
1.000 |
3.2 |
3.2 |
Q1 |
0.060 |
0.060 |
0.070 |
0.080 |
0.100 |
0.400 |
0.800 |
2 |
2 |
Start flowrate |
0.025 |
0.025 |
0.025 |
0.025 |
0.025 |
0.2 |
0.2 |
0.5 |
0.5 |
R-Q3/Q1 |
667 |
667 |
714 |
787 |
1000 |
625 |
500 |
500 |
500 |
Type evaluation parameter |
| ||||||||
Flowrate m³ |
Diameter | ||||||||
DN 40-1 1/2 |
DN 50-2 |
DN 65-2.5 |
DN 80-3 |
DN 100-4 |
DN 150-6 |
DN 200-8 |
DN 250-10 |
DN 300-12 | |
Q4 |
50 |
50 |
50 |
80 |
125 |
313 |
500 |
1250 |
1250 |
Q3 |
40 |
40 |
40 |
63 |
100 |
250 |
400 |
1000 |
1000 |
Q2 |
0.256 |
0.128 |
0.128 |
0.200 |
0.320 |
0.800 |
1.280 |
3.2 |
3.2 |
Q1 |
0.16 |
0.080 |
0.080 |
0.125 |
, |
0.500 |
0.800 |
2 |
2 |
R-Q3/Q1 |
250 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
500 |